日韩中文欧美在线视频

當前位置:日韩中文欧美在线视频  >  產品中心  >  電化學傳感器  >  實驗室離子電極  >  WS60CA043實驗室鈣離子電極
型號:WS60CA043

實驗室鈣離子電極

描敘:離(li)(li)(li)子(zi)(zi)選擇性(xing)(xing)電(dian)(dian)(dian)(dian)極(ji)(ji)分為(wei)復合電(dian)(dian)(dian)(dian)極(ji)(ji)、單(dan)(dan)電(dian)(dian)(dian)(dian)極(ji)(ji)、三合一電(dian)(dian)(dian)(dian)極(ji)(ji)。ISE的(de)敏感膜元件為(wei)離(li)(li)(li)子(zi)(zi)選擇性(xing)(xing)膜,在不同離(li)(li)(li)子(zi)(zi)濃度(du)條件下可(ke)產生(sheng)不同電(dian)(dian)(dian)(dian)位。因此,離(li)(li)(li)子(zi)(zi)選擇性(xing)(xing)測量電(dian)(dian)(dian)(dian)極(ji)(ji)與參比電(dian)(dian)(dian)(dian)極(ji)(ji)之間的(de)電(dian)(dian)(dian)(dian)位差(cha)發(fa)生(sheng)相應的(de)變(bian)化,可(ke)使用離(li)(li)(li)子(zi)(zi)計測量。這種電(dian)(dian)(dian)(dian)位差(cha)與溶液中的(de)相關(guan)離(li)(li)(li)子(zi)(zi)活度(du)成(cheng)正比。離(li)(li)(li)子(zi)(zi)活度(du)與樣品溶液的(de)濃度(du)和離(li)(li)(li)子(zi)(zi)強度(du)有關(guan)。常(chang)用的(de)濃度(du)單(dan)(dan)位為(wei) mol/L、mg/L 或(huo) ppm。

  • 中間商類別生產廠家
  • 更新系統耗時2026-03-14
  • 訪問共享量115
相關文章ARTICLES堅持創新驅動于稱得上更好的的搞定工作方案廠家直銷商!
詳細介紹
品牌其他品牌

WS60CA043實踐室鈣陽離子決定性金屬電極

一.WS60CA043離子電極

實驗室鈣離子電極


二.WS60CA043鈣離子電極枝術性能參數

測量范圍

0.02-4000ppm

電極類型

塑料型

斜率

22 -29mV 

重復性

滿滿量程的±2% (25℃)

響應速度

30s達95%

溫度范圍

無溫

壓力范圍

0-1Bar

pH范圍

4-10

干擾離子

Pb2+, Hg2+,Cu2+, Ni2+

主體材質

POM/PVC

電極規格

線長

一米

接頭

BNC


上新世紀6080年代(dai)(dai),越(yue)來越(yue)多調(diao)查組織(zhi)與金(jin)(jin)屬(shu)工(gong)(gong)業(ye)生產(chan)加工(gong)(gong)商設計規劃(hua)出(chu)了(le)陰(yin)化合(he)物選定(ding) 性金(jin)(jin)屬(shu)工(gong)(gong)業(ye)(ISE)并通過實踐(jian)教(jiao)學技術(shu)應(ying)(ying)用軟件(jian)。從今,ISE愈發完美,成為(wei)盡快(kuai)和(he)簡單化的(de)(de)陰(yin)化合(he)物活度(du)或鹽溶度(du)的(de)(de)估測做法。這些年來,ISE顧客(ke)可使(shi)用的(de)(de)一系統(tong)不靠譜的(de)(de)金(jin)(jin)屬(shu)工(gong)(gong)業(ye)、陰(yin)化合(he)物計與很(hen)實用的(de)(de)選耗材部件(jian)。不少的(de)(de)技術(shu)應(ying)(ying)用軟件(jian)被設計規劃(hua)代(dai)(dai)替法測定(ding)種(zhong)樣本中的(de)(de)陰(yin)化合(he)物鹽溶度(du)。舉(ju)例子,調(diao)味品(pin)(pin)、濃(nong)縮果汁、水(shui)、生活環境、產(chan)品(pin)(pin)、檢查是否品(pin)(pin)、養植(zhi)、無(wu)限(xian)監測網等多方面(mian)業(ye)務領域(yu)。

ISE的工作的方案

陰離子(zi)記(ji)憶性(xing)(xing)探針材(cai)料為(wei)組合探針材(cai)料、單(dan)電(dian)(dian)池箱、三(san)一體化(hua)探針材(cai)料。ISE的(de)敏感膜元件(jian)為(wei)離子(zi)選擇(ze)性(xing)(xing)膜,在不同離子(zi)濃度(du)條(tiao)件(jian)下可(ke)產生不同電(dian)(dian)位(wei)。因此,離子(zi)選擇(ze)性(xing)(xing)測量電(dian)(dian)極與(yu)參(can)比電(dian)(dian)極之間(jian)的(de)電(dian)(dian)位(wei)差發生相(xiang)應的(de)變化(hua),可(ke)使用離子(zi)計測量。這種電(dian)(dian)位(wei)差與(yu)溶液(ye)中的(de)相(xiang)關離子(zi)活(huo)度(du)成正(zheng)比。離子(zi)活(huo)度(du)與(yu)樣品溶液(ye)的(de)濃度(du)和離子(zi)強度(du)有關。常用的(de)濃度(du)單(dan)位(wei)為(wei) mol/L、mg/L 或 ppm。

能斯特式子對鋁離子活度與電勢差測試值期間的干系:

E=E0+2.3(RT/nF)•logai      (ai=Ci•γ )

E   工業電勢測量方法值,mV           E0  規定電位差(某參比(bi)電極常數),mV

R  氣物常數(shu),J/mol K  ;            T   工(gong)作溫度(du)表,K(標準規(gui)范供熱公司學工(gong)作溫度(du)表25°C (298.15 K))

n   陽(yang)離子(zi)電勢                          F   法拉第(di)常數,C/mol

ai   精(jing)確檢測的(de)(de)鐵(tie)鋁離子(zi)i的(de)(de)活度              Ci   精(jing)確檢測的(de)(de)鐵(tie)鋁離子(zi)i的(de)(de)濃度值

γ  總陰離子效果(guo)影響到指數公式

ISE的選性

正(zheng)鐵陰陽(yang)化(hua)合(he)物選用性金屬電極(ji)對(dui)獨特的(de)正(zheng)鐵陰陽(yang)化(hua)合(he)物測(ce)試活度(du)比較(jiao)敏感。只(zhi)不過,它是(shi)在必(bi)要程度(du)較(jiao)上還對(dui)其(qi)他一些正(zheng)鐵陰陽(yang)化(hua)合(he)物回應。要素正(zheng)鐵陰陽(yang)化(hua)合(he)物的(de)直接影響(xiang)代表為(wei)選用性因子K。示例(li):K (K+ / Na+)= 2.6•10?3 相對于鉀(jia)ISE而(er)言,K+首(shou)選性(xing)更(geng)高些,K+與Na+的抉擇性比率為(wei) 1:2.6*10-3 或385:1。就可以認識成鉀ISE關于K+的會抑制性(xing)是Na+的385倍。因此能斯特(te)方程的延伸方式,將干擾(rao)離子對(dui)于ISE的電位測量(liang)值E的作(zuo)用包含其中(zhong):

E=E0+2.3(RT/niF)•log [ai +∑(Kij•aj ni/nj)]

其它(ta)抑(yi)制(zhi)鋁離(li)子(zi)j的(de)所有(you) Kij 的總計

Kij 衡(heng)量鐵(tie)正離子i想必于(yu)擾亂(luan)鐵(tie)正離子j的(de)的(de)記憶性常數

aj 干攏陽離(li)子(zi)j的活(huo)度

ni 精確測量陰(yin)陽(yang)離子i的陰(yin)陽(yang)離子帶電(dian)粒子

nj 干(gan)撓(nao)化合(he)物j的化合(he)物電勢

電級的回應用時

達(da)到99%穩定電位所需(xu)的時間,在高濃度溶(rong)液(ye)中響(xiang)應(ying)很(hen)快,在低(di)至檢測極限的溶(rong)液(ye)中則會需(xu)要若干分鐘。全新和良好ISE的正常響(xiang)應(ying)時間:

晶胞與(yu)玻璃紙膜:3至(zhi)5分鐘

匯聚物膜:5至8分鐘(zhong)中速攪拌

亞鐵離子抗彎(wan)強(qiang)度轉(zhuan)換劑 (ISA)

用ISE進行(xing)離子測量(liang)時,使用ISA溶(rong)(rong)液(ye)(ye)很重要(yao)。ISA溶(rong)(rong)液(ye)(ye)或(huo)總(zong)離子強(qiang)度調節(jie)(jie)劑 (TISAB) 需要(yao)保持不同(tong)樣(yang)品與校(xiao)準(zhun)液(ye)(ye)的離子強(qiang)度相(xiang)對(dui)一致。以相(xiang)同(tong)比例(li)添加ISA溶(rong)(rong)液(ye)(ye)至樣(yang)品與標準(zhun)液(ye)(ye)中。關于(yu)如何選擇ISA溶(rong)(rong)液(ye)(ye),請(qing)參閱相(xiang)關資料。在大多數情況下,每100ml溶(rong)(rong)液(ye)(ye)添加2ml ISA溶(rong)(rong)液(ye)(ye)便足(zu)以調節(jie)(jie)樣(yang)品與標準(zhun)液(ye)(ye)的離子強(qiang)度。

常規化測量方法軟件

實驗室鈣離子電極


軟件與運維需知

調取(qu)ISE性(xing)能參數,確認選購的產品是否(fou)(fou)與(yu)應用環境相符;(如pH應用范圍、溫度范圍、是否(fou)(fou)帶壓(ya)水體、現場有無(wu)電磁干(gan)擾、供(gong)電干(gan)擾、有機溶劑(ji)腐蝕等)

用前,請認真仔細地(di)閱(yue)讀書操作的說(shuo)明書下載,

活性與校驗:上市前,感知器(qi)(qi)完(wan)成任務(wu)的基礎堿化和(he)校驗(yan)(yan)證實(shi);校驗(yan)(yan)前,請先提供好(hao)相(xiang)應設(she)備(如:正離(li)子計/mV計,燒杯、洗(xi)瓶、攪拌(ban)器(qi)(qi)、移液器(qi)(qi)、容量瓶等),通電活(huo)化傳感器(qi)(qi)24

鐘(zhong)頭往上,再開啟(qi)校(xiao)驗(yan)實際運營(ying)。(研(yan)究報(bao)告(gao)室用,個(ge)人建議死期校(xiao)驗(yan)或(huo)每一刻(ke)用前校(xiao)驗(yan),主要實際運營(ying)按研(yan)究報(bao)告(gao)室規范標準(zhun)還有用工作(zuo)經(jing)驗(yan))

參比電極存為:多日(ri)間應用,干放或(huo)凈泡于(yu)蒸餾水(shui)中;長時沒用,凈泡于(yu)低質量(liang)濃(nong)度標液中或(huo)保(bao)護(hu)措施帽中定時放水(shui)保(bao)障活性酶(mei)類膜觸及到水(shui)或(huo)訊(xun)問銷(xiao)售商。

還要注意項目:

檢定(ding)(ding)前、需認定(ding)(ding)義表通(tong)電相連接(jie)探針侵泡于水樣或同一(yi)水飽和溶液(ye)中超出24小時(浸泡超過48小時的電極(ji),標定(ding)(ding)數據準確性(xing)與穩定(ding)(ding)性(xing)較好)。

1.更換(huan)參(can)比探針:當參(can)比探針斜率<80%后,個人建(jian)議(yi)更換(huan)新的(de)參(can)比探針或膜頭;

2.電級使用壽命:≥6十一個月(yue)(非苛刻的環境);

ISE運營維護:

各個類別的(de)ISE需要(yao)采取不同的(de)維護措(cuo)施。在(zai)任(ren)何情(qing)況下,均需要(yao)小心處理敏感膜,以防發生任(ren)何機械損傷或化學變質。請(qing)勿觸摸聚(ju)合物膜。設置中低(di)攪拌(ban)速度,以免磁力(li)攪拌(ban)轉子跳動。

實驗室鈣離子電極


錯誤代碼去掉:

顯現現象(xiang)時,請了(le)解控(kong)制基礎性(xing)關鍵(jian)步驟根(gen)本錯(cuo)識種類(lei)。逐(zhu)條全面(mian)檢驗(yan)檢測(ce)控(kong)制平臺中(zhong)的現象(xiang),不可(ke)以盲(mang)目從眾操作方(fang)法或立刻建(jian)立聯系供(gong)給商調用(yong)化解細則。

ISE標準單位運作參照(資料主設備:ION2000型線下陰離子計)

多功能儀表(選(xuan)購)出廠(chang)均校(xiao)準(zhun)過,產品(pin)合格證(zheng)上都有(you)記錄數據。(出廠(chang)默(mo)認(ren)標準(zhun)液10ppm、100ppm)(全新電(dian)極初次使用,需在自來水中浸泡活化1-2 天),若需要自己校(xiao)準(zhun)、請按儀表說(shuo)明(ming)書步驟操作:

標準(zhun)化硫酸銅溶液施用次(ci)序,濃度值(zhi)從低到高、每(mei)臺(tai)標液參(can)比電(dian)極浸(jin)過時(shi)間約8分(fen)鐘,以(yi)mV信(xin)號穩定為準(zhun)。

誤差率的形成與制止

目的誤差度: 因鐵亞鐵正離(li)子探針(zhen)(zhen)片(pian)的關鍵技術(shu)相關問題構成環境(jing)室溫(wen)(wen)因素1℃的發生(sheng)變化、鐵亞鐵正離(li)子溶液濃(nong)度(du)(du)最少(shao)將所產(chan)生(sheng)±2%的誤差度(du)(du)、因此(ci)選(xuan)擇鐵亞鐵正離(li)子探針(zhen)(zhen)片(pian)是還要(yao)來環境(jing)室溫(wen)(wen)因素賠償費的,或復位(wei)與(yu)考試(shi)時(shi),盡已經保(bao)持(chi)試(shi)驗裝置(zhi)環境(jing)室溫(wen)(wen)因素不(bu)符;

亞鐵離子難度設定:所以測量(liang)液(ye)體中(zhong)都需(xu)加相對(dui)等量(liang)ISA,以確保樣品和標準液(ye)具有相同的離(li)子強(qiang)度;(因電極測量(liang)活度受(shou)到(dao)離(li)子強(qiang)度影(ying)響(xiang),影(ying)響(xiang)計算因子;如:活度a=濃度C×活度系數γ)

標液或打樣定制測量方法:較好采(cai)用為中低轉速混(hun)合(he)檢測;

干撓亞鐵離子或未命名干撓物:請查證涉(she)及正離子選澤(ze)性電(dian)極材料干預物導致度、很好(hao)規避或適當合理(li)補上;或咨訊ISE供(gong)應商。

線上電極材料的組裝與空氣流速

覺得安(an)轉(zhuan)途徑:調運式安(an)轉(zhuan);

空(kong)氣流動(dong)速度抑制:小編建議空(kong)氣流動(dong)速度40L/h。

需注意項目:

     新金屬(shu)電極(ji)斜率:

一價亞鐵離子:52~59mV/(NH4+、K+、Li+、NO3-、Cl-、F-、Br-、I-、BF4-、ClO4-、CN-、SCN-、Ag+、NH3、CO2、Na+) ;

二價鐵(tie)離子:22~29mV/(Ca2+、Mg2+、Hardness、Cu2+、Ba2+、Pb2+、Cd2+、S2-)(25℃);

一旦新金屬電極斜率看不到上表明的規模內,來執行這工作:

1.的準備新(xin)配置的標硫酸(suan)銅溶(rong)液;氣敏電極(ji)片修改(gai)鈦電極(ji)液;

2.純凈水清(qing)潔工作金屬參比(bi)電極、檢查(cha)報告神經敏感(gan)組件、金屬參比(bi)電極接法連接頭等;

3.連續檢定(ding)金(jin)屬電極好(hao)幾遍;

  4.如執行工作(zuo)這運(yun)作(zuo)后參比電極仍然不符(fu)合格率(lv),請(qing)與(yu)創造商水平業務(wu)團隊保(bao)持聯系。

在線上正離子確定性電級機械性能性能指標表(0-1000ppm范圍圖內檢測性能方面優

實驗室鈣離子電極


線下ISE應用材料

實驗室鈣離子電極










產品咨詢

留言框

  • 產品:

  • 您的單位:

  • 您的姓名:

  • 聯系電話:

  • 常用郵箱:

  • 省份:

  • 詳細地址:

  • 補充說明:

  • 驗證碼:

    請錄入測算報告(填上阿拉伯加數),如:三加四=7

TEL:15821255634

支付寶掃碼加入支付寶